Sodium hypochlorite generator (seawater type)

Features:

In order to inhibit the growth of microorganisms and organic matter in the water to form mud scale in the circulating water pipeline, which will reduce the water flow and reduce the heat exchange efficiency, the treatment method of adding sodium hypochlorite to the cooling water is adopted. The electrolytic seawater sodium hypochlorite generator uses natural seawater and adopts high-speed electrolysis to prepare high-activity sodium hypochlorite solution on site. The sodium hypochlorite solution is transported to the dosing point as a biocide through dehydrogenation storage, effectively killing microorganisms, sea creatures, algae and crustaceans in the water body, and preventing the blockage of circulating water pipelines and condenser systems.

Order

Service Hotline:

+86-400-832-6598
Product Description

The RNH series electrolytic seawater type sodium hypochlorite generator produced and developed by Jinan Ou Rui Industrial Co., Ltd.

In order to inhibit the growth of microorganisms and organic matter in the water to form mud scale in the circulating water pipeline, which will reduce the water flow and reduce the heat exchange efficiency, the treatment method of adding sodium hypochlorite to the cooling water is adopted. The electrolytic seawater sodium hypochlorite generator uses natural seawater and adopts high-speed electrolysis to prepare high-activity sodium hypochlorite solution on site. The sodium hypochlorite solution is transported to the dosing point as a biocide through dehydrogenation storage, effectively killing microorganisms, sea creatures, algae and crustaceans in the water body, and preventing the blockage of circulating water pipelines and condenser systems.


Principle summary of sodium hypochlorite generator

The main reaction process of sodium hypochlorite generator electrolysis can be expressed by the following equation:

NaCl+ H2O = NaClO + H2↑

Electrode reaction: anode: 2Cl--2e- → Cl2 cathode: 2H2O + 2e- → H2 + OH-

Solution reaction: 2NaOH + Cl2 → NaCl + NaClO + H2O

The electrolysis process of the electrolytic seawater type sodium hypochlorite generator is an electrochemical reaction process, which uses seawater and electricity as raw materials to make sodium hypochlorite solution. Although the chemical principle is simple, there are many technical indicators that affect the economy. Therefore, the design of the electrolysis electrode of the sodium hypochlorite generator should consider various factors, according to the compact and reasonable structure, energy-saving operation, convenient operation and maintenance, high operational reliability, and long equipment life. And other characteristics to design and manufacture. The sodium hypochlorite solution is accurately dosed, safe to operate, easy to use, easy to store, non-toxic to the environment, and there is no air leakage, and it can be dosed under any environmental working conditions.


Design standards

Basic reference design standards for coastal power stations:

GBT 22839-2010

Technical conditions of electrolytic seawater sodium hypochlorite generator

JB/T 2932-1999

Technical conditions of water treatment equipment

GBT 50050-2017

Design code for industrial circulating cooling water treatment

DL 5068-2014

Technical Regulations for Chemical Design of Thermal Power Plants

DL 5054-1996

Technical Regulations for the Design of Steam and Water Pipelines in Thermal Power Plants

GB 6450-86

Dry-type power transformer

GB 3859-93

Semiconductor power transformer

GB 3956-97

Copper and aluminum conductive cores of wires and cables for power installations

GBJ 87-1985

Design code for noise control of industrial enterprises

HG/T 20538-2016

Plastic lining (PP, PE, PVC) steel pipes and pipe fittings


System composition:

Seawater booster pump set

The seawater booster pump set provides the power source for the seawater filter and the back-end process to overcome the pressure drop.

Sea water filtration system

Filter seawater to micron level to prevent large particles from entering the electrolytic cell group and affecting the electrolysis process.

Electrolyzer group

The electrolytic cell group is the core unit of the whole set of equipment. The electrolytic cell group adopts titanium-based ruthenium and iridium rare metal oxide coating. The seawater passes through the electrolytic cell group through direct current catalysis to convert seawater's sodium chloride into sodium hypochlorite and hydrogen.

Rectifier transformer

Usually a rectifier transformer in the form of a silicon controlled rectifier is used, the voltage is changed to the required voltage through the transformer, and then a thyristor is used for controlled rectification. The input AC power is converted into DC power and the positive and negative poles provide power source and output to the electrolytic cell.

Storage and dehydrogenation tank

The generated sodium hypochlorite solution and hydrogen enter the storage and dehydrogenation tank through the pipeline for temporary storage and dehydrogenation process.

Dehydrogenation fan unit

The wind unit generally adopts the 1D+1S form, which blows a large amount of air into the storage and dehydrogenation storage tank to dilute the produced hydrogen and provides a power source to discharge the diluted hydrogen to a safe discharge point.

Dosing pump set

Use corrosion-resistant centrifugal pump to output to the dosing point.

Pickling system

The raw material is diluted with 31% hydrochloric acid and used for acid washing of the temporary storage power supply solution tank group to remove the scale of the electrolytic tank group.

Control System

The central control system of the complete set of equipment is used to control the automatic start and stop of the complete set of equipment and coordinated control with the outside.

Power distribution system

Allocate power sources for motors and related electrical drive equipment.

Optional accessories

The default standard configuration of PPE electrolyzer 1. Mesh type electrolyzer (MESH) 2. Concentric circular tube electrolyzer (CTE)


Application areas:

Electricity

Sea water lifts structures and kills marine life

Circulating water treatment

Industry

Petroleum and chemical circulating water treatment


Product Manual
Technical Parameters

Index

Unit

National standard(A)

Ourui standard

Power Efficiency

%

75

92

DC power consumption

kW.H / Kg.Cl2

4.5

3.4

Chlorine evolution potential

V (S.C.E)

1.13

1.04

Anode enhanced life test

Hr

30

100

Cathode service life

Y

20

Never damaged

Pickling cycle

D

30

36

Site layout size

Consult local business personnel


Flow Chart

Order Online

Advisory Message Leave the question you want to consult and the staff will get in touch with you in time
主站蜘蛛池模板: 欧美一级爆毛片 | 国产成人精品免费 | 久草热视频 | 成人在线观看不卡 | 成人欧美网站 | 亚洲精品综合一区在线 | 韩国美女爽快一毛片免费 | 久久精品国产福利 | 日韩在线小视频 | 一级a爰片久久毛片 | 国产乱肥老妇精品视频 | 九九国产视频 | 亚洲成a人片在线观看精品 亚洲成a人片在线观看中 | 亚洲国产老鸭窝一区二区三区 | 欧美一级毛片无遮挡 | 欧美一级亚洲一级 | 综合久久91 | 久久精品视频3 | 国产第一草草影院 | 中文字幕视频在线观看 | 99精品一区二区免费视频 | 一级片美国 | 成年午夜性爽快免费视频不卡 | 欧美精品久久久亚洲 | 韩国精品欧美一区二区三区 | 久草福利资源网站免费 | 国产在线观看一区二区三区四区 | 日本精品久久久久中文字幕 1 | 99久久成人 | 亚洲国产欧美在线人成 | 一个人看的免费高清视频日本 | 日韩在线 中文字幕 | 办公室紧身裙丝袜av在线 | 另类视频一区 | 日韩一级影院 | 欧美三区在线观看 | 国产成人精品免费视频网页大全 | 国产一级视频播放 | 国产特一级毛片 | 亚洲九九视频 | 在线a毛片免费视频观看 |